ENDNOTES
*1. Standard Test Conditions (STC): irradiance level 1000 W/m2, spectrum AM 1.5, cell temperature 25°C, and solar spectral irradiance per ASTM E 892. See APPENDIX, California Energy Commission A Guide to Photovoltaic (PV) System Design and Installation report, page 8, section 2.3.1 Factors Affecting Output, Standard Test Conditions
*2. No module power output tolerances are taken into consideration, as average tested module power output is equal to nameplate rating. The actual power output of a given module can vary up or down from the average. Manufacturers publish the range (i.e. 100W ± 5%) on the module specification sheet. See APPENDIX, Shell SQ160-PC specification sheet, Electrical Characteristics
*3. PTC ratings are calculated and published by the California Energy Commission (CEC). Module PTC ratings are available at the following CEC URL: http://www.consumerenergycenter.org/erprebate/eligible_pvmodules.html . See APPENDIX, California Energy Commission List of Eligible Photovoltaic Modules PTC rating listing
*4. Typical value of 7% referenced from the CEC published A Guide to Photovoltaic (PV) System Design and Installation consultant report. See APPENDIX, California Energy Commission A Guide to Photovoltaic (PV) System Design and Installation report, page 8, section 2.3.1 Factors Affecting Output, Dirt and Dust
*5. Typical value of 5% referenced from the CEC published A Guide to Photovoltaic (PV) System Design and Installation consultant report. See APPENDIX, California Energy Commission A Guide to Photovoltaic (PV) System Design and Installation report, page 8, section 2.3.1 Factors Affecting Output, Mismatch and wiring losses
*6. Typical value of 6% referenced from published CEC Inverter PTC ratings and inverter manufacturers specification sheets (SMA and Fronius). See APPENDIX, CEC List of Eligible Inverters PTC rating listing and SMA/Fronius product specification sheets
*7. Based on data from the National Renewable Energy Laboratory (NREL) published Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors for Los Angeles, CA. See APPENDIX, Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors, page 40, Los Angeles.
*8. Based on data from the CEC published A Guide to Photovoltaic (PV) System Design and Installation consultant report. See APPENDIX, California Energy Commission A Guide to Photovoltaic (PV) System Design and Installation report, page 9, section 2.3.2 Estimating System Energy Output, Sun angle and house orientation.
*9. Based on data from the National Renewable Energy Laboratory (NREL) published Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors. See APPENDIX, Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors, pages 37 (Dagget, CA) and 39 (Long Beach, CA).
*10. Based on data from the National Renewable Energy Laboratory (NREL) published Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors for a South facing, approximately 15 degree tilted system, located in Los Angeles, CA. See APPENDIX, Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors, page 40 (Los Angeles).
Contact AMECO for an honest expert solar evaluation for your home
|